Friday, February 18, 2011

Boler Trailer Modifications

How do Babycomp equipment to ensure contraceptive security so high? Take the Polycystic Ovary

La sicurezza contraccettiva o l’indicazione giornaliera di fertilità risulta essere così elevata e precisa (Indice Pearl 0,7 = 99.3%) grazie a più fattori:

* la sicurezza tecnica di LadyComp, and Pearly BabyComp ;
* the exact value of more than 700,000 cycles, which allowed the development of the program and more than 20 years of experience, work and microchip program, thanks to the intelligent neural system embedded in the devices, you adapting to change, with each day of use, increasing the woman's menstrual cycle which undergoes changes over time, due to natural hormonal changes.
signs * (output) that Pearly, LadyComp BabyComp and offer the woman are the result of an objective set of calculations, which exclude the risk arising from incorrect subjective assessments (such as happens in the symptomatic-thermal method) ;
* stored in the temperature Pearly, LadyComp BabyComp and is accurate to the hundredth of a ° C. This is because the temperature probe, which is supported under the tongue for the measurement, a thermometer is not normal but a special meter (thermistor), similar to quellli used in space technology in which the measure accuracy is important .
Also, just to ensure a precise figure, the measurement process is controlled by the program for approx. 100 times per second, and any anomalies are highlighted (eg if you open your mouth).

High accuracy of measurement and calculation

Pertanto, anche se misurata in modo sublinguale, la temperatura rilevata da Pearly, LadyComp e BabyComp è molto più precisa di quella misurata in modo rettale o vaginale anche se con termometri appositamente acquistati per l'utilizzo del metodo sintotermico.

Il dato memorizzato viene comparato con quelli derivanti dai calcoli delle medie delle temperature dei mesi precedenti (l'apparecchio calcola le medie delle temperature delle diverse fasi del ciclo: preovulatoria, postovulatoria e ovulatoria, quindi l'apparecchio si accorge se un dato è errato (per esempio per febbre).

Anche se nella pratica the everyday woman, who uses a Pearly, or LadyComp BabyComp only needs to measure its basal temperature, so sublingual, and confirm, where applicable, the menstrual data, the software works differently in the pre-ovulatory phase in which post- ovulatory. In fact, the temperature is one of the control parameters of the overall cycle of the woman and monitor the progestogen phase, but the calculations Biomathematics, which are crucial to indicate the BEGINNING of the fertile window of the cycle, take advantage of Algor very sophisticated, based on studies specific clinical, in the field of natural regulation of fertility.

As already mentioned, the only thing that is confirmed manually dalla donna è il dato mestruale (M), che può venire corretto e/o caricato manualmente nell'apparecchio, anche quando per uno o più giorni evitiamo di misurare la temperatura.

Il risultato di questo complesso insieme di calcoli che solo un software può eseguire è un'indicazione di "non fertilità" sicura al 99,3%.

Le colonne portanti dell’affidabilità di LadyComp, BabyComp e Pearly sono quindi: la stabilità del software e l'alta qualità delle componenti hardware (gli apparecchi sono al 100% made in Germany).

0 comments:

Post a Comment